Velarion Records
Free: one email when NPDES GA0001431 changes. Unsubscribe any time.

NPDES GA0001431 · Clean Water Act

MCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY, Smyrna, GA: NPDES GA0001431 discharge permit, effluent exceedances, inspections, penalties

MCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY, Smyrna, Georgia: Individual permit GA0001431, held by Georgia Power Company; Administratively continued; issued April 20, 2016, term to May 31, 2021; Fossil Fuel Electric Power Generation.

  • Temp. diff. between samp. & upstrm deg. F: 0 limits, 38 violations of any kind, 4 effluent exceedances, latest March 31, 1991, largest 40% over the limit.
  • pH: 8 limits, 181 violations of any kind, 3 effluent exceedances, latest March 31, 2013.
  • Solids, total suspended: 10 limits, 281 violations of any kind, 2 effluent exceedances, latest September 30, 2009, largest 5,273% over the limit.
  • Oil & Grease: 10 limits, 241 violations of any kind.
  • Chlorine, total residual: 6 limits, 195 violations of any kind.
  • Flow, in conduit or thru treatment plant: 12 limits, 157 violations of any kind.
  • Chlorine, total residual [dsg. time]: 3 limits, 98 violations of any kind.
  • Oil and grease [soxhlet extr.] tot.: 0 limits, 48 violations of any kind.
  • Chlorine, free available: 6 limits, 39 violations of any kind.
  • Temperature, water deg. fahrenheit: 0 limits, 35 violations of any kind.
  • Chromium, total [as Cr]: 6 limits, 32 violations of any kind.
  • Zinc, total [as Zn]: 6 limits, 30 violations of any kind.
  • Chlorination duration: 0 limits, 24 violations of any kind.
  • Flow, total: 2 limits, 15 violations of any kind.
  • Copper, total [as Cu]: 2 limits, 6 violations of any kind.
  • Iron, total [as Fe]: 2 limits, 6 violations of any kind.
  • Noel Statre 7Day Chronic Pimephales: 0 limits, 1 violation of any kind.

Other permits held by Georgia Power Company

MCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY among its neighbors

639 discharge permits are in the Little Suwanee Creek-Yellow River subwatershed (HUC 030701030301); GA0001431 is one. Its county: 66, 4 major; GA0001431 is minor permit.

Other permits in the Little Suwanee Creek-Yellow River subwatershed (HUC 030701030301)

What stands out

  • Its term runs 5 years and 41 days, April 20, 2016 to May 31, 2021; the term ended 1,962 days before EPA's file was loaded on October 14, 2026, and the file lists the permit as administratively continued.
  • No dated event in the 365 days to October 14, 2026.
  • 3 of its 17 pollutants on file have an effluent exceedance (18%); 12 are under a numeric limit; the largest exceedance is Solids, total suspended at 5,273% over its limit.
  • It is one of 45,725 discharge permits on the register in Georgia; the file names no program for it, and it is a minor discharger.

Identity

FacilityMCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY
PermitteeGeorgia Power Company
NPDES IDGA0001431
StatusAdministratively continued
TypeIndividual permit
ClassMinor
Facility typeNon-POTW
IssuedApril 20, 2016
ExpiresMay 31, 2021
AddressSmyrna, GA 30080
Receiving water impaired303(D) Listed
SubwatershedLittle Suwanee Creek-Yellow River (HUC 030701030301)
NAICS221112 – Fossil Fuel Electric Power Generation
SIC4911 – Electric Services
Other EPA IDs (FRS)ICIS-AIR source GA0000001306700003

NPDES GA0001431: effluent limits and exceedances

MCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY (NPDES GA0001431): 17 pollutants on file, 12 limited; 17 with a violation of any kind, 3 with an exceedance.

How exceedances are counted.

PollutantLimitsViolationsExceedancesLatestLargest, as filed
Temp. diff. between samp. & upstrm deg. F0384March 31, 199140% over the limit
pH81813March 31, 2013
Solids, total suspended102812September 30, 20095,273% over the limit
Oil & Grease102410
Chlorine, total residual61950
Flow, in conduit or thru treatment plant121570
Chlorine, total residual [dsg. time]3980
Oil and grease [soxhlet extr.] tot.0480
Chlorine, free available6390
Temperature, water deg. fahrenheit0350
Chromium, total [as Cr]6320
Zinc, total [as Zn]6300
Chlorination duration0240
Flow, total2150
Copper, total [as Cu]260
Iron, total [as Fe]260
Noel Statre 7Day Chronic Pimephales010

NPDES GA0001431: inspections, violations and enforcement

NPDES GA0001431 (MCDONOUGH-ATKINSON COMBINED-CYCLE FACILITY): no single-event violation, inspection, formal enforcement action and informal enforcement action on file.

Watch NPDES GA0001431

NPDES GA0001431: one email when its EPA record changes — $99/month.

Billing

Privacy

Permits near NPDES GA0001431

NPDES GA0001431: 17 pollutant rows, 0 dated events; ICIS-NPDES download, loaded October 14, 2026.