Clean Water Act discharge permit · NPDES AZ0023931

APACHE JUNCTION SEWER DISTRICT WWTP, Apache Junction, AZ: NPDES AZ0023931 discharge permit, effluent exceedances, inspections, penalties

APACHE JUNCTION SEWER DISTRICT WWTP, held by Superstition Mountains Community Facilities District No 1, holds NPDES permit AZ0023931. EPA’s file records it issued October 3, 2019 and expiring October 2, 2024. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedAPACHE JUNCTION SEWER DISTRICT WWTP
Permittee as filedSuperstition Mountains Community Facilities District No 1
NPDES IDAZ0023931
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMajor discharger
Facility typePublicly owned treatment works
ProgramPublicly owned treatment works
IssuedOctober 3, 2019
Expiration dateOctober 2, 2024
AddressApache Junction, AZ 85120
SubwatershedSiphon Draw (HUC 150501000803)
SIC4952 – Sewerage Systems

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant; the 60 with the most exceedances of 183 are shown.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Mercury, total recoverable52516September 30, 20152,150% over the limit
Cyanide, total [as CN]91612November 30, 2018175% over the limit
E. coli, colony forming units [CFU]31412June 30, 2020544% over the limit
Selenium, total recoverable52310June 30, 2019750% over the limit
Cyanide, dissolved std method0138May 31, 2014190% over the limit
Nitrogen, ammonia total [as N]376June 30, 2020500% over the limit
Solids, total suspended782April 30, 201342% over the limit
BOD, 5-day, 20 deg. C791January 31, 20077% over the limit
BOD, 5-day, percent removal131January 31, 202047% over the limit
Solids, suspended percent removal121January 31, 2020408% over the limit
Copper, total recoverable5130
Chromium, hexavalent dissolved [as Cr]590
Sulfide, total [as S]390
Chlorine, total residual580
Nickel, total recoverable150
Zinc, total recoverable150
Cadmium, total recoverable140
Oil & Grease430
Hardness, total [as CaCO3]330
Silver total recoverable130
Lead, total recoverable130
pH420
Chromium, total recoverable320
Flow, in conduit or thru treatment plant220
TU Static 4 Day Chronic Raphidocelis subcapitata (formerly Selenastrum capricornutum)220
TU Static Renewal 7-Day Chronic Ceriodaphnia dubia220
TU Static Renewal 7-Day Chronic Pimphales promelas220
Arsenic, total recoverable120
Thallium, total recoverable120
Beryllium, total recoverable [as Be]120
Antimony, total recoverable120
Pass/Fail Static 96Hr Acute Ceriodaphnia Dubia120
Pass/Fail Static 96 Hr Acute Pimephales Promelas120
Ammonia [as N] + unionized ammonia020
Temperature, water deg. centigrade210
Oxygen, dissolved [DO]110
Nitrogen, Kjeldahl, total [as N]110
Nitrite + Nitrate total [as N]110
Phosphorus, total [as P]110
Fluoride, total [as F]110
Boron, total recoverable110
Barium, total recoverable110
2-Methyl-4,6-dinitrophenol110
Diquat110
Manganese, total recoverable110
Dinoseb110
4-Bromophenyl phenyl ether110
Solids, total dissolved110
Iron, total recoverable400
Hydrogen sulfide300
Static 7Day Chronic Pimephales Promelas200
Tributyltin100
Uranium, total as U3O8100
Dichlorobromomethane100
Carbon tetrachloride100
1,2-Dichloroethane100
Bromoform100
Dibromochloromethane100
Chloroform100
Toluene100

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES AZ0023931.

Inspections

EPA’s inspection file holds no inspection for NPDES AZ0023931.

Formal enforcement and penalties

0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.

Informal enforcement

EPA’s informal enforcement file holds no action for NPDES AZ0023931.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, AZ0023931.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID AZ0023931 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers the Clean Water Act NPDES discharge permit AZ0023931 for the Apache Junction Sewer District WWTP in Apache Junction, AZ, held by Superstition Mountains Community Facilities District No 1, with its status listed as administratively continued. The figures listed are a discharger class of Major, 181 pollutants under a numeric limit, and 10 pollutants with an effluent exceedance.