Velarion Records
Follow this permit Velarion Records emails you this permit’s record, cited to the public filing, and tells you when the register changes it. Free.
We’ll email you a link to confirm. The continuous daily watch on every change is the paid alert. Unsubscribe any time.
Also free: The Pay Desk, the weekly executive pay briefing.

Clean Water Act discharge permit · NPDES COG591100

STRATTON WWTF, Stratton, CO: NPDES COG591100 discharge permit, effluent exceedances, inspections, penalties

STRATTON WWTF, held by Stratton Town of, holds NPDES permit COG591100, which discharges to Unnamed Tributray To Spring Creek To Unnamed Lake. EPA’s file records it issued October 25, 2024 and expiring December 31, 2029. The status and dates are as EPA’s permit file stood when Velarion loaded it (September 15, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedSTRATTON WWTF
Permittee as filedStratton Town of
NPDES IDCOG591100
Permit statusEffective
Permit typeCoverage under a general permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedOctober 25, 2024
Expiration dateDecember 31, 2029
AddressStratton, CO 80836
Receiving waterUnnamed tributray to Spring Creek to unnamed lake
SubwatershedOutlet Spring Creek (HUC 102500030511)

Cited to the EPA ICIS-NPDES permit file (ECHO download).

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant; the 60 with the most exceedances of 95 are shown.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Nitrogen, ammonia total [as N]4866May 31, 2026113% over the limit
BOD, 5-day, 20 deg. C633June 30, 202643% over the limit
BOD, 5-day, percent removal133June 30, 2026160% over the limit
Solids, total suspended222June 30, 20269% over the limit
Chlorine, total residual411December 31, 2025132% over the limit
E. coli411December 31, 202585% over the limit
Mercury, total [as Hg]210
Cyanide, total [as CN]110
Arsenic, total [as As]110
Cadmium, total [as Cd]110
Chromium, total [as Cr]110
Copper, total [as Cu]110
Lead, total [as Pb]110
Molybdenum, total [as Mo]110
Nickel, total [as Ni]110
Silver, total [as Ag]110
Zinc, total [as Zn]110
Selenium, total [as Se]110
Total phenols110
Flow, in conduit or thru treatment plant400
TU Static Renewal 7-Day Chronic Ceriodaphnia dubia300
TU Static Renewal 7-Day Chronic Pimphales promelas300
Plant capacity fact. percent of capacity200
pH200
Nitrogen, inorganic total200
Chloride [as Cl]200
Chromium, hexavalent dissolved [as Cr]200
Zinc, potentially dissolved200
Silver, potentially dissolved200
Copper, potentially dissolved200
Cadmium, potentially dissolvd200
Lead, potentially dissolvd200
Manganese, potentially dissolvd200
Nickel, potentially dissolvd200
Selenium, potentially dissolvd200
Uranium, potentially dissolvd200
Sulfide-hydrogen sulfide [undissociated]200
Perfluorooctanoic acid (PFOA)200
Perfluorobutanoic acid (PFBA)200
Perfluorooctanesulfonamide (PFOSA)200
Perfluoropentanoic acid (PFPeA)200
Perfluorohexanoic acid (PFHxA)200
Perfluoroheptanoic acid (PFHpA)200
Perfluorononanoic acid (PFNA)200
Perfluorodecanoic acid (PFDA)200
Perfluoroundecanoic acid (PFUnA)200
Perfluorododecanoic acid (PFDoA)200
Perfluorotridecanoic acid (PFTrDA)200
Perfluorotetradecanoic acid (PFTeDA)200
N-ethyl perfluorooctanesulfonamidoethanol (NEtFOSE)200
N-methyl perfluorooctanesulfonamidoethanol (NMeFOSE)200
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)200
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)200
Perfluorobutanesulfonic acid (PFBS)200
Perfluorodecanesulfonic acid (PFDS)200
Perfluoroheptanesulfonic acid (PFHpS)200
Perfluorohexanesulfonic acid (PFHxS)200
Perfluorooctanesulfonic acid (PFOS)200
1H,1H,2H,2H-Perfluorohexane sulfonic acid (4:2 FTS)200
1H,1H,2H,2H-Perfluorooctane sulfonic acid (6:2 FTS)200

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES COG591100.

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, COG591100.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID COG591100 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded September 15, 2026.

What this page shows

This public-records page covers NPDES permit COG591100 for the STRATTON WWTF in Stratton, CO, held by Stratton Town of and discharging to an unnamed tributary to Spring Creek. The page lists 95 pollutants on file, 95 under a numeric limit, 19 with a violation of any kind, and 6 with an effluent exceedance.