Velarion Records
Follow this permit Velarion Records emails you this permit’s record, cited to the public filing, and tells you when the register changes it. Free.
We’ll email you a link to confirm. The continuous daily watch on every change is the paid alert. Unsubscribe any time.
Also free: The Pay Desk, the weekly executive pay briefing.

Clean Water Act discharge permit · NPDES COR900972

FRONT RANGE LANDFILL, Erie, CO: NPDES COR900972 discharge permit, effluent exceedances, inspections, penalties

FRONT RANGE LANDFILL, held by Waste Connections Inc, holds NPDES permit COR900972, which discharges to Unnamed Tributary - Little Dry Creek. EPA’s file records it issued June 26, 2012 and expiring June 30, 2017. The status and dates are as EPA’s permit file stood when Velarion loaded it (September 15, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedFRONT RANGE LANDFILL
Permittee as filedWaste Connections Inc
NPDES IDCOR900972
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeCoverage under a general permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
ProgramIndustrial stormwater
IssuedJune 26, 2012
Expiration dateJune 30, 2017
AddressErie, CO 80516
Receiving waterUnnamed tributary - Little Dry Creek
SubwatershedLittle Dry Creek (HUC 101900030601)
Other EPA IDs (FRS)RCRA handler COR000007377

Cited to the EPA ICIS-NPDES permit file (ECHO download); cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Solids, total suspended8170
Iron, total [as Fe]8160

EPA’s effluent violation file records no exceedance of a numeric limit for NPDES COR900972.

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES COR900972.

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, COR900972.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID COR900972 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded September 15, 2026.

What this page shows

The Velarion Records page covers Clean Water Act discharge permit NPDES COR900972 for FRONT RANGE LANDFILL in Erie, CO, held by Waste Connections Inc, with a minor discharger class of 2 and an administratively continued status. The page lists 0 pollutants under a numeric limit and 0 pollutants with an effluent exceedance, and it cites the watershed Little Dry Creek (HUC 101900030601).