SOUTHERN ERECTORS INC, Pensacola, FL: NPDES FLR05H727 discharge permit, effluent exceedances, inspections, penalties

SOUTHERN ERECTORS INC, held by Southern Erectors Inc, holds NPDES permit FLR05H727. EPA’s file records it issued October 28, 2019 and expiring October 27, 2024. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedSOUTHERN ERECTORS INC
Permittee as filedSouthern Erectors Inc
NPDES IDFLR05H727
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeCoverage under a general permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
ProgramIndustrial stormwater
IssuedOctober 28, 2019
Expiration dateOctober 27, 2024
Issuing agencyFlorida Department of Environmental Protection
AddressPensacola, FL 32526
SubwatershedCaney Bayou-Perdido River (HUC 031401060703)
NAICS332313 – Plate Work Manufacturing
SIC3443 – Fabricated Plate Work (Boiler Shops)
Other EPA IDs (FRS)RCRA handler FLR000211532

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download; cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Nitrite + Nitrate total [as N]320
Iron, total recoverable320
Zinc, total recoverable320
Aluminum, total recoverable320

EPA’s effluent violation file records no exceedance of a numeric limit for NPDES FLR05H727.

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
December 14, 2017WW Storm Water Non-Construction - Failure to develop any or adequate SWPPP/SWMPST6
December 14, 2017WW Storm Water Non-Construction - Failure to Implement SWPPP/SWMPST6
December 14, 2017WW Storm Water Non-Construction - Failure to Maintain RecordsST6
December 14, 2017WW Storm Water Non-Construction - Failure to properly operate and maintain BMPsST6
December 14, 2017WW Storm Water Non-Construction - Failure to properly install/implement BMPsST6
December 14, 2017WW Storm Water Non-Construction - Failure to MonitorST6

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, FLR05H727.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID FLR05H727 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers Clean Water Act NPDES permit FLR05H727, held by SOUTHERN ERECTORS INC in Pensacola, FL, with the permit administratively continued after its expiration. The facts list the permit as a Minor Discharger class 4 with 0 pollutants under a numeric limit and 0 pollutants with an effluent exceedance, within the Caney Bayou-Perdido River watershed (HUC 031401060703).