Clean Water Act discharge permit · NPDES KS0200010

BOLINGER, VAN, Cheney, KS: NPDES KS0200010 discharge permit, effluent exceedances, inspections, penalties

BOLINGER, VAN, held by Van Bolinger Farm, holds NPDES permit KS0200010, which discharges to Ninnescah R, S Fk (110300151). EPA’s file records it issued August 21, 2023 and expiring September 30, 2028. The status and dates are as EPA’s permit file stood when Velarion loaded it (September 15, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedBOLINGER, VAN
Permittee as filedVan Bolinger Farm
NPDES IDKS0200010
Permit statusEffective
Permit typeIndividual permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedAugust 21, 2023
Expiration dateSeptember 30, 2028
Issuing agencyKansas Department of Health and Environment (KDHE)
AddressCheney, KS 67025
Receiving waterNinnescah R, S Fk (110300151)
SubwatershedNester Creek-South Fork Ninnescah River (HUC 110300150306)

Cited to the EPA ICIS-NPDES permit file (ECHO download).

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Naphthalene122June 30, 20248,765% over the limit
pH220
Benzene200
Lead, total recoverable100
Methyl tert-butyl ether [MTBE]100
1,2-Dichloroethane100
Toluene100
Ethylbenzene100
Flow, in conduit or thru treatment plant100
Total Petroleum Hydrocarbons - Diesel100
Total Petroleum Hydrocarbons - Gasoline100
Xylene [mix of m+o+p]100
Hydrocarbons, petroleum100

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

EPA’s single-event violation file, as loaded, holds no violation for NPDES KS0200010.

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, KS0200010.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID KS0200010 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded September 15, 2026.

What this page shows

This public-records page covers NPDES permit KS0200010, held by Van Bolinger Farm at Cheney, KS, which discharges to the Ninnescah R, S Fk (110300151) within the Nester Creek-South Fork Ninnescah River subwatershed (HUC 110300150306). The page lists 13 pollutants on file, 13 of them under a numeric limit, 2 with a violation of any kind, and 1 with an effluent exceedance.