ABBEVILLE, CITY OF, Abbeville, LA: NPDES LA0039748 discharge permit, effluent exceedances, inspections, penalties

ABBEVILLE, CITY OF, held by CITY OF ABBEVILLE, holds NPDES permit LA0039748, which discharges to Youngs North Coulee. EPA’s file records it issued September 16, 2016 and expiring October 31, 2021. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedABBEVILLE, CITY OF
Permittee as filedCITY OF ABBEVILLE
NPDES IDLA0039748
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMajor discharger
Facility typePublicly owned treatment works
ProgramPublicly owned treatment works
IssuedSeptember 16, 2016
Expiration dateOctober 31, 2021
AddressAbbeville, LA 70510
Receiving waterYOUNGS NORTH COULEE
SubwatershedYoungs South Coulee-Vermilion River (HUC 080801030202)
SIC4952 – Sewerage Systems

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
BOD, carbonaceous [5 day, 20 C]63318July 31, 2022110% over the limit
Solids, total suspended63012September 30, 2021483% over the limit
Nitrogen, ammonia total [as N]6212October 31, 2007190% over the limit
Coliform, fecal general2122January 31, 200022% over the limit
Lead, total [as Pb]222March 31, 2014111% over the limit
pH2131March 31, 2015
Whole effluent toxicity051September 30, 201699,999% over the limit
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas2160
NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas2160
NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas2160
Flow, in conduit or thru treatment plant2120
Pass/Fail Static Renewal 7Day Chronic Pimephales promelas2120
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia2120
NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia2120
NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia2120
Coef Of Var Static Renewal 7Day Chronic Pimephales promelas1120
Pass/Fail Static Renewal 7 Day Chronic Ceriodaphnia dubia280
Coef Of Var Static Renewal 7Day Chronic Ceriodaphnia dubia180
Oxygen, dissolved [DO]170
Solids, total dissolved630
Whole Effluent Toxicity [WET] - C. dubia200
Whole Effluent Toxicity [WET] - P. promelas200

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
December 31, 2023Reporting Violations - Failure to submit required report (non-DMR non-pretreatment)ST6
September 7, 2023Management Practice Violations - Failure to Develop Adequate SPCC PlanST6
September 7, 2023Management Practice Violations - Failure to Implement SPCC PlanST6
September 7, 2023Failure to properly conduct industrial stormwater inspectionsST6
September 7, 2023Failure to develop, maintain, or get approval of an adequate SWPPP (industrial stormwater)ST6
September 7, 2023Permit Violations - Violation Specified in CommentST6
September 7, 2023Permit Violations - CWA §308 Failure to submit required permit application informationST6
December 31, 2022Permit Violations - Violation Specified in CommentST6
December 31, 2019Reporting Violations - Failure to submit required report (non-DMR non-pretreatment)ST6

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, LA0039748.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID LA0039748 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers NPDES permit LA0039748, held by CITY OF ABBEVILLE for its publicly owned treatment works in Abbeville, LA, which discharges to Youngs North Coulee within the Youngs South Coulee-Vermilion River watershed (HUC 080801030202). The permit is listed as administratively continued, with a Major Discharger class, 21 pollutants under a numeric limit, and 7 pollutants with an effluent exceedance.