Clean Water Act discharge permit · NPDES MI0023400

LANSING WWTP, Lansing, MI: NPDES MI0023400 discharge permit, effluent exceedances, inspections, penalties

LANSING WWTP, held by City of Lansing, holds NPDES permit MI0023400, which discharges to Grand River. EPA’s file records it issued January 30, 2020 and expiring October 1, 2022. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedLANSING WWTP
Permittee as filedCity of Lansing
NPDES IDMI0023400
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMajor discharger
Facility typePublicly owned treatment works
ProgramPublicly owned treatment works
IssuedJanuary 30, 2020
Expiration dateOctober 1, 2022
Issuing agencyState
AddressLansing, MI 48917
Receiving waterGrand River
Receiving water impaired303(D) Listed
SubwatershedHerron Creek-Red Cedar River (HUC 040500040508)
Program components on fileBiosolids, CSO, POTW, Pretreatment
NAICS221320 – Sewage Treatment Facilities
SIC4952 – Sewerage Systems
Other EPA IDs (FRS)RCRA handler MID980619209

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download; cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Coliform, fecal general67913April 30, 20262,900% over the limit
Nitrogen, ammonia total [as N]171126July 31, 202595% over the limit
BOD, carbonaceous [5 day, 20 C]16655October 31, 202599,999% over the limit
pH6691December 31, 2022
Solids, total suspended12720
Flow, in conduit or thru treatment plant10660
Phosphorus, total [as P]8540
BOD, 5-day, 20 deg. C0480
Oxygen, dissolved [DO]4330
Chlorine, total residual4240
Perfluorooctanoic acid (PFOA)4220
Perfluorooctanesulfonate4140
Mercury, total [as Hg]4100
Solids, total360
Arsenic, dry weight360
Selenium, dry weight360
Copper, dry weight360
Cadmium, dry weight360
Nitrogen, total Kjeldahl360
Molybdenum, sludge, total, dry weight [as Mo]360
Zinc, sludge, total, dry weight [as Zn]360
Lead, sludge, total, dry weight [as Pb]360
Nickel, sludge, total, dry weight [as Ni]360
Nitrogen, sludge, total, dry weight [as N]360
Mercury, sludge, total, dry weight [as Hg]360
Potassium, sludge, total, dry weight [as K]360
Phosphorus, sludge, total, dry weight [as P]360
Solids, suspended percent removal230
BOD, carb-5 day, 20 deg C, percent removal220
Toxicity, choice of species400
Static 48 Hr Chronic Pimphales Promelas400
Toxicity [acute], Ceriodaphnia dubia200
TU Static 24 Hr Acute Pimephales promelas200

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
February 19, 2025Failure to enforce standards, local limits, and reporting requirements (>15% SNC SIU) (Level II)ST6
February 19, 2025Failure to issue/reissue control mechanisms to at least 90% of SIU/CIUs w/in 6 months (Level II)ST6
October 18, 2023Monitoring Violations - Failure to Monitor for Non-Toxicity RequirementsST6
January 27, 2022Pretreatment - Failure to Enforce Against I/UST6
January 27, 2022Failure to enforce standards, local limits, and reporting requirements (>15% SNC SIU) (Level II)ST6
April 1, 2021Monitoring Violations - Failure to Monitor for Non-Toxicity RequirementsST6
January 1, 2018Pretreatment - Failure to Develop/Enforce StandardsST6
January 1, 2018Monitoring Violations - Failure to Monitor for Non-Toxicity RequirementsST6
January 1, 2018Monitoring Violations - Invalid/Unrepresentative SampleST6
January 1, 2018Failure to enforce standards, local limits, and reporting requirements (>15% SNC SIU) (Level II)ST6
October 31, 2017Reporting Violations - Late Submittal of DMRsST6

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, MI0023400.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID MI0023400 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers NPDES permit MI0023400 for the LANSING WWTP in Lansing, MI, held by City of Lansing and discharging to the Grand River, with the permit listed as administratively continued and a Major Discharger class. The page lists 4 pollutants under a numeric limit and 4 pollutants with an effluent exceedance, with the permit's issue and expiration dates as they stood when the record was loaded.