Velarion Records
Follow this permit Velarion Records emails you this permit’s record, cited to the public filing, and tells you when the register changes it. Free.
We’ll email you a link to confirm. The continuous daily watch on every change is the paid alert. Unsubscribe any time.
Also free: The Pay Desk, the weekly executive pay briefing.

Clean Water Act discharge permit · NPDES NE0140091

STANDARD IRON & WIRE WORKS, INC, Grand Island, NE: NPDES NE0140091 discharge permit, effluent exceedances, inspections, penalties

STANDARD IRON & WIRE WORKS, INC, held by Standard Iron & Wire Works, Inc., holds NPDES permit NE0140091, which discharges to Utilities Ditch To Wood River. EPA’s file records it issued May 30, 2025 and expiring June 30, 2030. The status and dates are as EPA’s permit file stood when Velarion loaded it (September 15, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedSTANDARD IRON & WIRE WORKS, INC
Permittee as filedStandard Iron & Wire Works, Inc.
NPDES IDNE0140091
Permit statusEffective
Permit typeIndividual permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedMay 30, 2025
Expiration dateJune 30, 2030
Issuing agencyNDEE
AddressGrand Island, NE 68803
Receiving waterUtilities Ditch to Wood River
SubwatershedEagles Lake-Wood River (HUC 102001020404)
Other EPA IDs (FRS)RCRA handler NER000504753; ICIS-AIR source NE0000003107900143

Cited to the EPA ICIS-NPDES permit file (ECHO download); cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Zinc, total [as Zn]233December 31, 202519,089% over the limit
Copper, total [as Cu]222December 31, 2025128% over the limit
Chromium, total [as Cr]211December 31, 202550% over the limit
pH200
Cyanide, total [as CN]200
Cadmium, total [as Cd]200
Lead, total [as Pb]200
Nickel, total [as Ni]200
Silver, total [as Ag]200
Flow, in conduit or thru treatment plant200
Organics, total toxic [TTO]200

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
September 4, 2025Failure to conduct self-inspectionsST6

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, NE0140091.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID NE0140091 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded September 15, 2026.

What this page shows

This public-records page covers Clean Water Act discharge permit NPDES NE0140091, held by Standard Iron & Wire Works, Inc. in Grand Island, NE, which discharges to Utilities Ditch to Wood River within the Eagles Lake-Wood River subwatershed (HUC 102001020404). The permit is listed as Effective and as a Minor discharger class, with 11 pollutants under a numeric limit and 3 pollutants with an effluent exceedance.