Velarion Records
Follow this permit Velarion Records emails you this permit’s record, cited to the public filing, and tells you when the register changes it. Free.
One more press on the next page sends it; there is no link to click in an email. The continuous daily watch on every change is the paid alert. Unsubscribe any time.
Also free: The Pay Desk, the weekly executive pay briefing.

Clean Water Act discharge permit · NPDES NJ0051608

MONMOUTH CNTY RECLAMATION CENTER, Tinton Falls Boro, NJ: NPDES NJ0051608 discharge permit, effluent exceedances, inspections, penalties

MONMOUTH CNTY RECLAMATION CENTER holds NPDES permit NJ0051608. EPA’s file records it issued March 10, 2014 and expiring March 31, 2019.

MONMOUTH CNTY RECLAMATION CENTER, Tinton Falls Boro, New Jersey: Individual industrial user permit NJ0051608; Administratively continued (past its expiration date and still in force until reissued); issued March 10, 2014, term to March 31, 2019; Solid Waste Landfill.

  • Copper, total [as Cu]: 2 limits, 3 violations of any kind, 3 effluent exceedances, latest January 31, 2026, largest 124% over the limit.
  • Zinc, total [as Zn]: 2 limits, 2 violations of any kind, 2 effluent exceedances, latest May 31, 2024, largest 96% over the limit.
  • Flow, in conduit or thru treatment plant: 4 limits, 9 violations of any kind, 1 effluent exceedance, latest June 30, 2018, largest 3% over the limit.
  • Nitrogen, nitrate total [as NO3]: 2 limits, 3 violations of any kind, 1 effluent exceedance, latest August 31, 2021, largest 13% over the limit.
  • Solids, total suspended: 2 limits, 6 violations of any kind, 0 effluent exceedances.
  • pH: 2 limits, 4 violations of any kind, 0 effluent exceedances.
  • Cadmium, total [as Cd]: 2 limits, 4 violations of any kind, 0 effluent exceedances.
  • Lead, total [as Pb]: 2 limits, 4 violations of any kind, 0 effluent exceedances.
  • Petrol hydrocarbons, total recoverable: 2 limits, 4 violations of any kind, 0 effluent exceedances.
  • Mercury, total [as Hg]: 2 limits, 4 violations of any kind, 0 effluent exceedances.
  • Perfluorotridecanoic acid (PFTrDA): 0 limits, 3 violations of any kind, 0 effluent exceedances.
  • Perfluorotetradecanoic acid (PFTeDA): 0 limits, 3 violations of any kind, 0 effluent exceedances.
  • Hexafluoropropylene oxide dimer acid (HFPO-DA): 0 limits, 3 violations of any kind, 0 effluent exceedances.
  • Nitrogen, ammonia total [as N]: 2 limits, 2 violations of any kind, 0 effluent exceedances.
  • Cyanide, total [as CN]: 2 limits, 2 violations of any kind, 0 effluent exceedances.
  • Arsenic, total [as As]: 2 limits, 2 violations of any kind, 0 effluent exceedances.
  • Chromium, total [as Cr]: 2 limits, 2 violations of any kind, 0 effluent exceedances.
  • Nickel, total [as Ni]: 2 limits, 2 violations of any kind, 0 effluent exceedances.
  • Perfluorododecanoic acid (PFDoA): 0 limits, 2 violations of any kind, 0 effluent exceedances.
  • Perfluoroundecanoic acid (PFUnA): 0 limits, 1 violation of any kind, 0 effluent exceedances.
  • BOD, 5-day, 20 deg. C: 2 limits, 0 violations of any kind, 0 effluent exceedances.
  • February 6, 2024: WW Storm Water Non-Construction - Failure to Conduct Inspections (ST6).
  • February 6, 2024: WW Storm Water Non-Construction - Failure to Implement SWPPP/SWMP (ST6).
  • September 24, 2019: Monitoring Violations - Invalid/Unrepresentative Sample (EP6).
  • September 24, 2019: Management Practice Violations - Improper Operation and Maintenance (EP6).
  • September 24, 2019: Effluent Violations - Narrative Effluent Violation (EP6).
  • May 24, 2018: Permit Violations - Violation Specified in Comment (ST6).
  • May 24, 2018: Pretreatment - IU Violation of Pretreatment Standards (ST6).

MONMOUTH CNTY RECLAMATION CENTER among its neighbors

Its county holds 1,086, 7 of them major permits; NJ0051608 is a minor permit.

Other permits in the county

Identity

Facility as filedMONMOUTH CNTY RECLAMATION CENTER
Permittee as filedMONMOUTH CNTY RECLAMATION CENTER
NPDES IDNJ0051608
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual industrial user permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedMarch 10, 2014
Expiration dateMarch 31, 2019
AddressTinton Falls Boro, NJ 07753
Receiving water impaired303(D) Listed
NAICS562212 – Solid Waste Landfill
SIC4953 – Refuse Systems
Other EPA IDs (FRS)RCRA handler NJR000065011; ICIS-AIR source NJ0000003402520597

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Copper, total [as Cu]233January 31, 2026124% over the limit
Zinc, total [as Zn]222May 31, 202496% over the limit
Flow, in conduit or thru treatment plant491June 30, 20183% over the limit
Nitrogen, nitrate total [as NO3]231August 31, 202113% over the limit
Solids, total suspended260
pH240
Cadmium, total [as Cd]240
Lead, total [as Pb]240
Petrol hydrocarbons, total recoverable240
Mercury, total [as Hg]240
Perfluorotridecanoic acid (PFTrDA)030
Perfluorotetradecanoic acid (PFTeDA)030
Hexafluoropropylene oxide dimer acid (HFPO-DA)030
Nitrogen, ammonia total [as N]220
Cyanide, total [as CN]220
Arsenic, total [as As]220
Chromium, total [as Cr]220
Nickel, total [as Ni]220
Perfluorododecanoic acid (PFDoA)020
Perfluoroundecanoic acid (PFUnA)010
BOD, 5-day, 20 deg. C200

Inspections, violations and enforcement

DateWhat EPA recordedAgency
February 6, 2024WW Storm Water Non-Construction - Failure to Conduct InspectionsST6
February 6, 2024WW Storm Water Non-Construction - Failure to Implement SWPPP/SWMPST6
September 24, 2019Monitoring Violations - Invalid/Unrepresentative SampleEP6
September 24, 2019Management Practice Violations - Improper Operation and MaintenanceEP6
September 24, 2019Effluent Violations - Narrative Effluent ViolationEP6
May 24, 2018Permit Violations - Violation Specified in CommentST6
May 24, 2018Pretreatment - IU Violation of Pretreatment StandardsST6

Inspections

EPA’s inspection file holds no inspection for NPDES NJ0051608.

Formal enforcement and penalties

0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.

Informal enforcement

EPA’s informal enforcement file holds no action for NPDES NJ0051608.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, NJ0051608.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This page is a Velarion Records entry for NPDES permit NJ0051608, held by MONMOUTH CNTY RECLAMATION CENTER in Tinton Falls Boro, NJ, and classed as a minor discharger under an individual industrial user permit. The permit's status is listed as administratively continued, with an issue date of March 10, 2014 and an expiration date of March 31, 2019. The page reports 4 pollutants under a numeric limit and 4 pollutants with an effluent exceedance.