Velarion Records
Follow this permit Velarion Records emails you this permit’s record, cited to the public filing, and tells you when the register changes it. Free.
We’ll email you a link to confirm. The continuous daily watch on every change is the paid alert. Unsubscribe any time.
Also free: The Pay Desk, the weekly executive pay briefing.

Clean Water Act discharge permit · NPDES TX0074438

GIBBONS CREEK STEAM ELECTRIC STATION, Grimes County, TX: NPDES TX0074438 discharge permit, effluent exceedances, inspections, penalties

GIBBONS CREEK STEAM ELECTRIC STATION, held by TEXAS MUNICIPAL POWER AGENCY, holds NPDES permit TX0074438, which discharges to Unnamed Ditch; Gibbons Creek. EPA’s file records it issued December 1, 2015 and expiring May 1, 2020. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedGIBBONS CREEK STEAM ELECTRIC STATION
Permittee as filedTEXAS MUNICIPAL POWER AGENCY
NPDES IDTX0074438
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMajor discharger
Facility typeNot a publicly owned treatment works
IssuedDecember 1, 2015
Expiration dateMay 1, 2020
AddressGrimes County, TX 77830
Receiving waterUNNAMED DITCH; GIBBONS CREEK
SubwatershedPanther Creek (HUC 120701030703)
SIC4911 – Electric Services
Other EPA IDs (FRS)RCRA handler TXD000751073; ICIS-AIR source TX0000004818500002

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download; cross-program IDs from EPA’s FRS facility-registry crosswalk.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
BOD, 5-day, 20 deg. C44327May 31, 20241,597% over the limit
Oil & Grease61915March 31, 2025945% over the limit
Solids, total suspended83714June 30, 2023532% over the limit
Chlorine, total residual43211October 31, 201881% over the limit
Sulfate, total [as SO4]664February 29, 201621% over the limit
Oxygen demand, chem. [high level] [COD]244December 31, 202427% over the limit
pH10252May 31, 2019
Selenium, total [as Se]852March 31, 2021139% over the limit
Aluminum, total [as Al]022December 31, 200874% over the limit
LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas4280
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas4260
LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia4240
LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia4240
NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia4200
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia4190
Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas4190
NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas4190
NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia4190
NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas4190
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia4180
Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas4180
Flow, in conduit or thru treatment plant10110
Whole effluent toxicity - retest #1640
E. coli440
LC50 Pass/Fail Static 24Hr Acute D. Pulex240
LC50 Pass/Fail Static 24Hr Acute Pimephales promelas240
Whole effluent toxicity - retest #2620
Temperature, water deg. fahrenheit220
Copper, total [as Cu]220
Iron, total [as Fe]220
Solids, total dissolved610
Chloride [as Cl]400

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
January 22, 2025Permit Violations - Violation Specified in CommentST6
December 7, 2022Permit Violations - Violation Specified in CommentST6
January 16, 2019Permit Violations - Violation Specified in CommentST6

Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, TX0074438.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID TX0074438 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers Clean Water Act discharge permit NPDES TX0074438 for GIBBONS CREEK STEAM ELECTRIC STATION in Grimes County, TX, held by TEXAS MUNICIPAL POWER AGENCY and discharging to Unnamed Ditch; Gibbons Creek within watershed HUC 120701030703. The page lists a permit status of administratively continued, a Major Discharger class, 9 pollutants under a numeric limit, and 31 pollutants with an effluent exceedance.