CITY OF SEADRIFT WWTP, Seadrift, TX: NPDES TX0116190 discharge permit, effluent exceedances, inspections, penalties

CITY OF SEADRIFT WWTP, held by SEADRIFT, CITY OF, holds NPDES permit TX0116190, which discharges to Pipeline To San Antonio Bay/Hynes B. EPA’s file records it issued September 4, 2009 and expiring July 1, 2014. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.

Identity

Facility as filedCITY OF SEADRIFT WWTP
Permittee as filedSEADRIFT, CITY OF
NPDES IDTX0116190
Permit statusAdministratively continued (past its expiration date and still in force until reissued)
Permit typeIndividual permit
Discharger classMinor discharger
Facility typeNot a publicly owned treatment works
IssuedSeptember 4, 2009
Expiration dateJuly 1, 2014
AddressSeadrift, TX 77983
Receiving waterPIPELINE TO SAN ANTONIO BAY/HYNES B
SubwatershedSan Antonio Bay-Espiritu Santo Bay (HUC 121004030200)
SIC4941 – Water Supply

Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.

Effluent limits and exceedances

An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant.

Pollutant or measureLimitsViolations, any kindEffluent exceedancesLatest exceedanceLargest exceedance, as filed
Copper, total [as Cu]89515March 31, 201836,937% over the limit
Flow, in conduit or thru treatment plant2744June 30, 201434,577% over the limit
pH2590
Solids, total dissolved1310

Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.

Inspections, violations and enforcement

DateWhat EPA recordedAgency
March 2, 2017Permit Violations - Discharge Without a Valid PermitST6

Inspections

EPA’s inspection file holds no inspection for NPDES TX0116190.

Formal enforcement and penalties

0 formal actions, 0 of them with a penalty assessed. Federal and state penalties are separate figures from separate authorities and are shown as each was filed, never added together.

Informal enforcement

EPA’s informal enforcement file holds no action for NPDES TX0116190.

Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.

Watch this permit

One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, TX0116190.

Start the watch

How often?
  • One permit holder — $99/month
  • One watershed — $2,990/year
  • One state — $4,990/year
  • The whole register — $18,000/year

How we handle your data → Privacy

EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID TX0116190 there.

Nearby on the register

Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.

What this page shows

This public-records page covers the Clean Water Act discharge permit NPDES TX0116190 for the CITY OF SEADRIFT WWTP in Seadrift, TX, held by SEADRIFT, CITY OF, which discharges to Pipeline To San Antonio Bay/Hynes B within the San Antonio Bay-Espiritu Santo Bay watershed (HUC 121004030200). The permit is listed as administratively continued, a Minor Discharger class 4, with 2 pollutants under a numeric limit and 2 pollutants with an effluent exceedance.