Clean Water Act discharge permit · NPDES TX0116581
JOHN HARGROVE WATER RECLAMATION FACILITY, Pearland, TX: NPDES TX0116581 discharge permit, effluent exceedances, inspections, penalties
- Administratively continuedPermit status
- MajorDischarger class
- 55Pollutants under a numeric limit
- 9Pollutants with an effluent exceedance
JOHN HARGROVE WATER RECLAMATION FACILITY, held by CITY OF PEARLAND, holds NPDES permit TX0116581, which discharges to Marys Creek, Clear Creek Above Tida. EPA’s file records it issued January 18, 2019 and expiring January 18, 2024. The status and dates are as EPA’s permit file stood when Velarion loaded it (October 14, 2026); EPA’s free Detailed Facility Report on ECHO carries the permit’s current standing.
Identity
| Facility as filed | JOHN HARGROVE WATER RECLAMATION FACILITY |
|---|---|
| Permittee as filed | CITY OF PEARLAND |
| NPDES ID | TX0116581 |
| Permit status | Administratively continued (past its expiration date and still in force until reissued) |
| Permit type | Individual permit |
| Discharger class | Major discharger |
| Facility type | Publicly owned treatment works |
| Program | Publicly owned treatment works |
| Issued | January 18, 2019 |
| Expiration date | January 18, 2024 |
| Address | Pearland, TX 77584 |
| Receiving water | MARYS CREEK, CLEAR CREEK ABOVE TIDA |
| Subwatershed | Clear Creek-Frontal Galveston Bay (HUC 120402040100) |
| SIC | 4952 – Sewerage Systems |
Cited to the EPA ICIS-NPDES permit file (ECHO download) and EPA’s NAICS/SIC and component files, the same download.
Effluent limits and exceedances
- 62Pollutants on file
- 55Under a numeric limit
- 37With a violation of any kind
- 9With an effluent exceedance
An effluent exceedance is a discharge monitoring report value over the permit’s numeric limit (EPA’s violation code E90). A violation of any kind also counts a report not filed. Each row is EPA’s own count for that pollutant; the 60 with the most exceedances of 62 are shown.
| Pollutant or measure | Limits | Violations, any kind | Effluent exceedances | Latest exceedance | Largest exceedance, as filed |
|---|---|---|---|---|---|
| Nitrogen, ammonia total [as N] | 3 | 105 | 102 | August 31, 2024 | 1,230% over the limit |
| BOD, carbonaceous [5 day, 20 C] | 3 | 79 | 76 | December 31, 2025 | 598% over the limit |
| E. coli | 2 | 62 | 60 | May 31, 2026 | 60,552% over the limit |
| Solids, total suspended | 3 | 59 | 56 | January 31, 2024 | 830% over the limit |
| Flow, in conduit or thru treatment plant | 3 | 21 | 12 | January 31, 2024 | 128% over the limit |
| Whole Effluent Toxicity [WET] - P. promelas | 8 | 8 | 8 | December 31, 2023 | 65% over the limit |
| Coliform, fecal general | 0 | 18 | 4 | September 30, 2008 | 148% over the limit |
| pH | 3 | 6 | 2 | July 31, 2024 | |
| Oxygen, dissolved [DO] | 1 | 3 | 1 | July 31, 2023 | 20% over the limit |
| Conductivity | 0 | 17 | 0 | ||
| Nitrogen, total [as N] | 0 | 17 | 0 | ||
| Phosphorus, total [as P] | 0 | 17 | 0 | ||
| Potassium, total [as K] | 0 | 17 | 0 | ||
| pH, in soil | 0 | 17 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Ceriodaphnia dubia | 4 | 6 | 0 | ||
| Whole effluent toxicity | 0 | 6 | 0 | ||
| Low Flow Pass/Fail Survival Test Static Renewal 7 Day Chronic Pimephales promelas | 4 | 4 | 0 | ||
| NOEC Lethal Static Renewal 7 Day Chronic Pimephales promelas | 4 | 4 | 0 | ||
| NOEC Sub-Lethal Static Renewal 7 Day Chronic Pimephales promelas | 4 | 4 | 0 | ||
| Pass/Fail Sub-Lethal Static Renewal 7 Day Chronic Pinephales promelas | 4 | 4 | 0 | ||
| LOEC Lethal Survival Static Renewal 7 Day Chronic Pimephales promelas | 4 | 4 | 0 | ||
| LOEC Sub-Lethal Reproduction Static Renewal 7 Day Chronic Pimephales promelas | 4 | 4 | 0 | ||
| Chromium, sludge, total, dry weight [as Cr] | 5 | 3 | 0 | ||
| Solids, total dissolved | 3 | 3 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute D. Pulex | 1 | 3 | 0 | ||
| LC50 Pass/Fail Static 24Hr Acute Pimephales promelas | 1 | 3 | 0 | ||
| Whole effluent toxicity - retest #1 | 7 | 2 | 0 | ||
| Whole effluent toxicity - retest #2 | 7 | 2 | 0 | ||
| Level of pathogen requirements achieved | 2 | 1 | 0 | ||
| Description of pathogen option used | 2 | 1 | 0 | ||
| Vector attraction reduction alternative used | 2 | 1 | 0 | ||
| Pollutant table from 503.13 | 1 | 1 | 0 | ||
| Arsenic, dry weight | 5 | 0 | 0 | ||
| Selenium, dry weight | 3 | 0 | 0 | ||
| Copper, dry weight | 3 | 0 | 0 | ||
| Cadmium, dry weight | 3 | 0 | 0 | ||
| Molybdenum, sludge, total, dry weight [as Mo] | 3 | 0 | 0 | ||
| Zinc, sludge, total, dry weight [as Zn] | 3 | 0 | 0 | ||
| Lead, sludge, total, dry weight [as Pb] | 3 | 0 | 0 | ||
| Nickel, sludge, total, dry weight [as Ni] | 3 | 0 | 0 | ||
| Mercury, sludge, total, dry weight [as Hg] | 3 | 0 | 0 | ||
| Nickel, total [as Ni] | 2 | 0 | 0 | ||
| Fecal coliform | 1 | 0 | 0 | ||
| Polychlorinated biphenyls [PCBs] | 1 | 0 | 0 | ||
| Toxicity characteristic leaching procedure | 1 | 0 | 0 | ||
| Annual whole sludge application rate | 1 | 0 | 0 | ||
| Ann. amt sludge disposed by other method | 1 | 0 | 0 | ||
| Annual amt of sludge incinerated | 1 | 0 | 0 | ||
| Annual sludge production, total | 1 | 0 | 0 | ||
| Annual amount of sludge land applied | 1 | 0 | 0 | ||
| Annual amt. sludge disposed surface unit | 1 | 0 | 0 | ||
| Annual amt sludge disposed in landfill | 1 | 0 | 0 | ||
| Annual amt sludge transported interstate | 1 | 0 | 0 | ||
| Unit w/liner/leachate collection system | 1 | 0 | 0 | ||
| Compliance w/part 258 sludge requirement | 1 | 0 | 0 |
Cited to the EPA ICIS-NPDES limits and effluent violations files (ECHO download); up to 60 rows shown, most exceedances first.
Inspections, violations and enforcement
- 4Single-event violations
| Date | What EPA recorded | Agency |
|---|---|---|
| March 4, 2026 | Permit Violations - Violation Specified in Comment | ST6 |
| October 24, 2023 | Permit Violations - Violation Specified in Comment | ST6 |
| November 3, 2020 | Permit Violations - Violation Specified in Comment | ST6 |
| November 15, 2018 | Permit Violations - Violation Specified in Comment | ST6 |
Velarion’s copy of EPA’s ICIS-NPDES files does not include the inspections, formal enforcement actions and informal enforcement actions files, so this page shows none of them. EPA’s free Detailed Facility Report on ECHO lists this permit’s inspections, enforcement actions and penalties.
Cited to the EPA ICIS-NPDES violation, inspection and enforcement files (ECHO download); up to 50 rows of each shown, newest first.
Watch this permit
One permit holder, $99/month. Watch the register for one permit holder and the places and receiving waters tied to its permits. Choose “One permit holder” and enter this permit’s NPDES ID, TX0116581.
Start the watch
- One permit holder — $99/month
- One watershed — $2,990/year
- One state — $4,990/year
- The whole register — $18,000/year
How we handle your data → Privacy
EPA publishes a free Detailed Facility Report for every permit on ECHO: its compliance status quarter by quarter, its inspections, and its enforcement actions and penalties. EPA also sends free notices of new inspections and enforcement actions through ECHO Notify; enter NPDES ID TX0116581 there.
Nearby on the register
- Discharge permits in Pearland
- Every permit record in Pearland, A to Z
- Discharge permits in Texas
- Every permit record in Texas, A to Z
Figures from EPA’s ICIS-NPDES download, loaded October 14, 2026.